ลงชื่อเข้าใช้
NFPA20 Standard Mutil-stage Vertial Turbine Fire Pump Capacities Up To 10,000 GPM For Firefighting Use
Standard and Range
Standards
NFPA20, UL, FM, EN12845,CCCF
Performance Ranges
UL : Q: 250-5000GPM H:80-300PSI
FM: Q: 250-5000GPM H:80-300PSI
CCCF: Q:15-300L/S H:0.60-2.0Mpa
NFPA20: Q: 250-5000GPM H:80-300PSI
How It Works:
The vertical turbine pump is normally driven by an AC electric induction motor or a diesel engine via a right angle drive. The end of the pump consists of a rotating impeller that is joined to a shaft and guides the well water into a diffuser casing known as a bowl.
Pumps with multi-stage arrangements use several impellers on a single shaft to generate higher pressure that would be required for pumping water from deeper wells or where higher pressure (head) is required at ground level.
A vertical turbine pump works when water comes through the pump from the bottom through a bell-shaped device known as a suction bell. The water then moves into the first stage impeller, which increases the velocity of the water. The water then moves into the diffuser casing directly above the impeller, where the high velocity energy is transformed into high pressure. The diffuser casing also guides the fluid into the next impeller located directly above the diffuser casing. The process goes on through all the stages in the pump.
After leaving the diffuser casing, the water passes in a vertical column pipe and rises toward the surface. The rotating shaft within the column is propped at 3 to 5 foot intervals using sleeve bushings that are set within the column and they are lubricated by the water as it moves past them. The pump also has a discharge head at the surface which allows the flow to change direction toward the discharge pipe. An upright standing high thrust A.C. motor is fitted above the pump’s discharge head.
|
|
ความคิดเห็นเกี่ยวกับตัวสินค้า
Review Images | Delete |
การชำระเงิน |
กรุณาโอนเงินเข้าบัญชี ธนาคาร กสิกรไทย สาขา คลอง 6 ธัญบุรี ชื่อบัญชี บจก.เจช้อปดีแอล เลขที่บัญชี 119-347-595-3 โปรติดต่อฝ่ายขาย 061-5597151 ก่อนการโอน |
|
|
หมายเลขอ้างอิง: 4141
Capacity: 200 GPM – 2000 GPM
Pressures: 40 – 355 psi
Maximum Working Pressures: 290 to 395 PSI
Speed: 1480,1760, 2900,2980, 3000 RPM
Dynamically Balanced Impeller extends bearing life and ensures smoother operation.
Designed and built as per UL 448 AND NFPA20 for maximum reliability.
Constructed in variety of metallurgies.
Available in 50 Hz and 60 Hz.
Drivers with gear boxes at electric and diesel speeds.
Designed for easy maintenance without interfering with piping.
Open line shaft, water lubricated construction for ease of maintenance.
Self-Venting Design eliminates vapor lock and the need for automatic air release valve
2